Ruggedization levels
ApisSys products support up to four ruggedization levels, ranging from standard air flow for development and benign environment use to rugged conduction cooled dedicated to deployed defense applications in harsh environment.
Air flow, Standard AS (VITA 47 EAC4* |
Air flow, Rugged AR (VITA 47 EAC6)* |
Conduction Standard CS (VITA 47 ECC3)* |
Conduction Rugged CR (VITA47 ECC4)* |
|
---|---|---|---|---|
Operating Temperature |
0°C to +55°C (1) (8 CFM airfl ow at sea level) |
-40 to +70ºC (1) (8 CFM airfl ow at sea level) |
-40°C to +70°C (Card Edge) |
-40°C to +85°C (Card Edge) |
Non Operating Temperature |
-40°C to +85°C | -50°C to +100°C | -50°C to +100°C | -55°C to +105°C |
Operating Vibration (Random) |
5Hz - 100Hz +3 dB/octave 100Hz-1kHz = 0.04 g2/Hz 1kHz - 2kHz -6 dB/octave |
5Hz - 100Hz +3 dB/octave 100Hz - 1kHz = 0.04 g2/Hz 1kHz - 2kHz -6 dB/octave |
5Hz - 100Hz +3 dB/octave 100Hz - 1kHz = 0.1 g2/Hz 1kHz - 2kHz -6 dB/octave |
5Hz - 100Hz +3 dB/octave 100Hz - 1kHz = 0.1 g2/Hz 1kHz - 2kHz -6 dB/octave |
Operating Shock |
20g, 11 millisecond, half-sine | 20g, 11 millisecond, half-sine | 40g, 11 millisecond, half-sine | 40g, 11 millisecond, half-sine |
Operating Relative Humidity |
0% to 95% non-condensing |
0% to 95% non-condensing |
0% to 95% non-condensing |
0% to 95% non-condensing |
Operating Altitude |
@ 0 to 10,000 ft with adequate airflow |
@ 0 to 30,000 ft with adequate airflow |
@ 0 to 30,000 ft | @ 0 to 60, 000 ft |
Conformal Coating |
No | Optional (default acrylic 1B31) | Yes (default acrylic 1B31) |
Yes (default acrylic 1B31) |
*Reference to ANSI-VITA standard VITA 47 (r2) for the listed parameters
only. Temperature cycling or other not listed VITA 47 requirements on
demand